{"id":155180,"date":"2013-10-15T12:02:34","date_gmt":"2013-10-15T12:02:34","guid":{"rendered":"http:\/\/climalife.com\/une-renovation-optimisee-avec-une-solution-combinant-un-condenseur-a-technologie-micro-canaux-de-chez-hk-refrigeration-et-le-performax-lt-r-407f-distribue-par-climalife\/"},"modified":"2023-04-11T08:36:23","modified_gmt":"2023-04-11T08:36:23","slug":"une-renovation-optimisee-avec-une-solution-combinant-un-condenseur-a-technologie-micro-canaux-de-chez-hk-refrigeration-et-le-performax-lt-r-407f-distribue-par-climalife","status":"publish","type":"post","link":"https:\/\/climalife.com\/fr\/une-renovation-optimisee-avec-une-solution-combinant-un-condenseur-a-technologie-micro-canaux-de-chez-hk-refrigeration-et-le-performax-lt-r-407f-distribue-par-climalife\/","title":{"rendered":"Une r\u00e9novation optimis\u00e9e avec une solution combinant un condenseur \u00e0 technologie micro-canaux de chez HK REFRIGERATION et le Performax\u2122 LT (R-407F) distribu\u00e9 par Climalife."},"content":{"rendered":"<p>Cr\u00e9\u00e9e en 1980 par Monsieur J.M. Gouville, l&#8217;entreprise n&#8217;a cess\u00e9 de cro\u00eetre et d&#8217;apporter \u00e0 ses clients un service de proximit\u00e9 et de qualit\u00e9. Aujourd&#8217;hui dirig\u00e9e par St\u00e9phane Gouville, la soci\u00e9t\u00e9 est implant\u00e9e dans 4 agences en Basse-Normandie et emploie 56 techniciens.\u00a0 <br><br><br \/>\nLors de l&#8217;\u00e9tude du projet, il a \u00e9t\u00e9 rapidement \u00e9tabli que l&#8217;installation de froid \u00e9tait condamn\u00e9e \u00e0 court terme car elle fonctionnait aux R-22, R-502 et R-404A. Dans le cadre de l&#8217;agrandissement du magasin, les parties prenantes du projet arrivent au choix de la n\u00e9cessit\u00e9 de refaire une installation neuve. <br><br><\/p>\n<p>M. Daboudet, responsable du chantier pour Gouville SAS est soucieux de proposer \u00e0 ses clients des solutions technico-\u00e9conomiques pertinentes, respectueuses de l&#8217;environnement et anticipant les contraintes l\u00e9gislatives en perspective. Ce dernier propose alors le Performax<sup>TM<\/sup> LT, pr\u00e9conis\u00e9 par Climalife et dont il a entendu parler par des confr\u00e8res l&#8217;ayant d\u00e9j\u00e0 mis en \u0153uvre. Le Performax<sup>TM<\/sup> LT est associ\u00e9 \u00e0 un condenseur \u00e0 technologie micro-canaux qui r\u00e9duit le co\u00fbt total des \u00e9quipements. <br><br><\/p>\n<p>L&#8217;utilisateur final, de son c\u00f4t\u00e9 avait \u00e9galement d\u00e9j\u00e0 eu connaissance des performances du R-407F. Dans le contexte actuel de r\u00e9vision de la F-Gas, le GWP du Performax<sup>TM<\/sup> LT (1824) est un argument de poids par rapport au R-404A (GWP 3922). Le R-407F est donc retenu comme fluide unique pour le froid positif et n\u00e9gatif de l&#8217;installation.\u00a0 <br><br><br \/>\n<strong><br \/>\n<\/strong><\/p>\n<h2><strong>Une mise en \u0153uvre maitris\u00e9e ! <\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsCase_studiesLeclerc4.jpg\" alt=\"\" width=\"260\" height=\"233\" align=\"right\" border=\"0\" hspace=\"5\" vspace=\"5\" \/>Il convient de d\u00e9placer \u00e0 l&#8217;ext\u00e9rieur du local technique l&#8217;installation actuelle toujours en fonctionnement et de proc\u00e9der \u00e0 l&#8217;installation et la mise en route de la nouvelle unit\u00e9 sans perte d&#8217;activit\u00e9. Les travaux se d\u00e9roulent de janvier \u00e0 juin 2013 et l&#8217;installation est compos\u00e9e de 3 centrales.<\/p>\n<p>Dans un premier temps, apr\u00e8s avoir d\u00e9plac\u00e9 l&#8217;installation en fonctionnement \u00e0 l&#8217;ext\u00e9rieur, J\u00e9r\u00f4me Daboudet et son \u00e9quipe de 6 techniciens proc\u00e8dent \u00e0 la mise en place des \u00e9quipements des chambres froides n\u00e9gatives. <br><br><\/p>\n<p>La centrale n\u00e9gative de chez HK REFRIGERATION type MOPSH 4N 6HE-28 est compos\u00e9e de 4 compresseurs \u00e0 pistons herm\u00e9tiques accessibles BITZER 6HE28Y. Elle est calcul\u00e9e pour une puissance frigorifique de 50,4 kW \u00e0 un r\u00e9gime (-36 \/ 42\u00b0C). Cette centrale alimente l&#8217;ensemble des postes n\u00e9gatifs (chambres froides et meubles de vente ferm\u00e9s). Pour ne provoquer aucune perte d&#8217;activit\u00e9 commerciale, les vitrines sont mises en service les unes apr\u00e8s les autres. <br><br><\/p>\n<p>Les deux autres centrales sont utilis\u00e9es pour le froid positif.<br \/>\nLa premi\u00e8re type MOPSH 5P 6GE-34Y est calcul\u00e9e pour une puissance de 344 kW \u00e0 un r\u00e9gime (-10 \/ 42\u00b0C). Elle est constitu\u00e9e de 5 compresseurs \u00e0 pistons herm\u00e9tiques accessibles BITZER 6GE34Y et alimente des meubles frigorifiques de ventes positifs. La seconde centrale positive de type MOPSH 4P 4FE-28 comprend 4 compresseurs \u00e0 pistons herm\u00e9tiques accessibles BITZER 4FE28Y et est dimensionn\u00e9e pour une puissance de 222 kW \u00e0 un r\u00e9gime (-10 \u00e0 42\u00b0C). Cette centrale alimente les chambres froides et les couloirs positifs.<br \/>\nUn r\u00e9cup\u00e9rateur de chaleur type d\u00e9surchauffeur est \u00e9galement mis en place sur cette centrale afin d&#8217;approvisionner un ballon d&#8217;eau chaude sanitaire de 2000 L. <br><br><\/p>\n<p>L&#8217;installation est \u00e9quip\u00e9e d&#8217;un condenseur \u00e0 technologie micro-canaux de marque HK REFRIGERATION disposant de 3 circuits ind\u00e9pendants. Cette technologie largement \u00e9prouv\u00e9e par le groupe Lennox dans les applications de conditionnement d&#8217;air propose des condenseurs construits de fa\u00e7on modulaire autour de batteries micro-canaux dispos\u00e9es en W.<br \/>\nElle r\u00e9alise des \u00e9quipements plus compacts et plus l\u00e9gers du fait de batteries aluminium disposant d&#8217;une haute densit\u00e9 de performance r\u00e9pondant ainsi aux contraintes de plus en plus fortes de r\u00e9duction de l&#8217;encombrement des \u00e9quipements. <br><br><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsCase_studieslecelrc3.jpg\" alt=\"\" width=\"324\" height=\"220\" align=\"right\" border=\"0\" hspace=\"5\" vspace=\"5\" \/><\/p>\n<p>Autre atout de cette technologie, par rapport \u00e0 des batteries \u00e0 ailettes classiques, les micro-canaux ont permis de r\u00e9duire la charge en fluide frigorig\u00e8ne de l&#8217;installation de mani\u00e8re significative d&#8217;environ 125 kg soit une r\u00e9duction de l&#8217;ordre de 20% sur la charge totale de l&#8217;installation frigorifique. Ainsi, associ\u00e9 \u00e0 l&#8217;utilisation du R-407F, fluide ayant un GWP plus faible que le R-404A, l&#8217;exploitant r\u00e9duit de plus de 140 Tonnes \u00e9quivalent CO2 \/ an son empreinte carbone li\u00e9e \u00e0 l&#8217;\u00e9mission directe de gaz \u00e0 effet de serre. <br><br><\/p>\n<p>Par ailleurs, le niveau de performance procur\u00e9e par la technologie micro-canaux combin\u00e9e \u00e0 l&#8217;utilisation de moteurs EC assure une consommation \u00e9nerg\u00e9tique r\u00e9duite par rapport \u00e0 des batteries ailet\u00e9es traditionnelles minimisant ainsi l&#8217;empreinte carbone de l&#8217;exploitant li\u00e9e \u00e0 l&#8217;\u00e9mission indirecte de gaz \u00e0 effet de serre. <br><br><\/p>\n<p>Ce condenseur de marque HK REFRIGERATION (MXW EC1 8P18) est dimensionn\u00e9 pour fonctionner au Performax<sup>TM<\/sup> LT et dispose de 3 circuits ind\u00e9pendants. Cela r\u00e9gule de mani\u00e8re autonome le rejet des 3 centrales de compression. De ce fait, un seul condenseur dispos\u00e9 en toiture est mis en place pour le fonctionnement de l&#8217;installation frigorifique r\u00e9duisant le temps d&#8217;installation.\u00a0 <br><br><\/p>\n<p>La combinaison de cette technologie avec le Performax<sup>TM<\/sup> LT permet d&#8217;avoir une approche environnementale plus large en r\u00e9duisant la charge de fluide dans l&#8217;installation, en diminuant d&#8217;autant son empreinte carbone et en baissant sa consommation \u00e9nerg\u00e9tique. De plus, comme le souligne Climalife, le Performax<sup>TM<\/sup> LT est plus facile \u00e0 d\u00e9tecter que le R-404A, ce qui restreint le taux de fuite annuel. Les b\u00e9n\u00e9fices pour l&#8217;utilisateur final sont donc multiples. <br><br><\/p>\n<p>Le d\u00e9fi a \u00e9t\u00e9 relev\u00e9 et les objectifs atteints puisque l&#8217;installation fonctionne \u00e0 pr\u00e9sent totalement et aucun arr\u00eat d&#8217;activit\u00e9 n&#8217;a \u00e9t\u00e9 n\u00e9cessaire. Le responsable du chantier, M. Daboudet et M. Henry Directeur de l&#8217;hypermarch\u00e9 sont satisfaits de cette association technologique performante et fiable. <br><br><\/p>\n<h2><strong>Relev\u00e9s de fonctionnement :<\/strong><\/h2>\n<p><!-- [if gte mso 9]><xml>  <w:WordDocument>   <w:View>Normal<\/w:View>   <w:Zoom>0<\/w:Zoom>   <w:HyphenationZone>21<\/w:HyphenationZone>   <w:PunctuationKerning\/>   <w:ValidateAgainstSchemas\/>   <w:SaveIfXMLInvalid>false<\/w:SaveIfXMLInvalid>   <w:IgnoreMixedContent>false<\/w:IgnoreMixedContent>   <w:AlwaysShowPlaceholderText>false<\/w:AlwaysShowPlaceholderText>   <w:Compatibility>    <w:BreakWrappedTables\/>    <w:SnapToGridInCell\/>    <w:WrapTextWithPunct\/>    <w:UseAsianBreakRules\/>    <w:DontGrowAutofit\/>    <w:UseFELayout\/>   <\/w:Compatibility>   <w:BrowserLevel>MicrosoftInternetExplorer4<\/w:BrowserLevel>  <\/w:WordDocument> <\/xml><![endif]--><\/p>\n<table class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">Unit\u00e9<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">Mesure<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">Calcul<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">Centrale positive n\u00b02<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">Centrale n\u00e9gative<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Fluide Performax\u2122 LT<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Date<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">15\/05\/2013<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">15\/05\/2013<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Pression d\u2019\u00e9vaporation<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">Bar<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">2,68<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">0,55<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9rature d\u2019\u00e9vaporation<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">-10<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">-31<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9rature d&#8217;aspiration au compresseur<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\" align=\"center\">-6,2<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">1,3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Pression de condensation<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">Bar<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">18,72<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">10,62<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9rature de condensation \u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">45<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9rature de refoulement<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">90,3<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9rature entr\u00e9e d\u00e9tendeur<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">39,8<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">20,4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">CP1 BITZER<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">4 FE 28Y 40P<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">6 HE 28Y 40P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Puissance absorb\u00e9e du compresseur<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">KVA<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">21,40<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">11,53<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Puissance frigorifique du compresseur<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">kW<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">53,5<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">26,8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Puissance de r\u00e9jection du compresseur<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">kW<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">74,9<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">38,3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">COP frigorifique<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">2,5<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">2,33<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Charge en fluide frigorig\u00e8ne Kg<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">Kg<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">250<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"151\">\n<p class=\"MsoNormal\">Temp\u00e9ratures ambiantes ext\u00e9rieures<\/p>\n<\/td>\n<td valign=\"top\" width=\"53\">\n<p class=\"MsoNormal\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"59\">\n<p class=\"MsoNormal\">X<\/p>\n<\/td>\n<td valign=\"top\" width=\"56\">\n<p class=\"MsoNormal\">\n<\/td>\n<td valign=\"top\" width=\"144\">\n<p class=\"MsoNormal\">11<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p class=\"MsoNormal\">9<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- [if gte mso 9]><xml>  <w:LatentStyles DefLockedState=\"false\" LatentStyleCount=\"156\">  <\/w:LatentStyles> <\/xml><![endif]--><!-- [if gte mso 10]> \n\n\n\n<style>  \/* Style Definitions *\/  table.MsoNormalTable \t{mso-style-name:\"Tableau Normal\"; \tmso-tstyle-rowband-size:0; \tmso-tstyle-colband-size:0; \tmso-style-noshow:yes; \tmso-style-parent:\"\"; \tmso-padding-alt:0cm 5.4pt 0cm 5.4pt; \tmso-para-margin:0cm; \tmso-para-margin-bottom:.0001pt; \tmso-pagination:widow-orphan; \tfont-size:10.0pt; \tfont-family:\"Times New Roman\"; \tmso-fareast-font-family:\"Times New Roman\"; \tmso-ansi-language:#0400; \tmso-fareast-language:#0400; \tmso-bidi-language:#0400;} <\/style>\n\n\n\n <![endif]--><\/p>\n<div style=\"text-align: left;\" align=\"center\"><br><br><\/div>\n<p>Temp\u00e9rature des postes &#8211; installation n\u00e9gative :<br \/>\n-24\u00b0C\/-26\u00b0C pour les meubles frigorifiques de vente verticaux ferm\u00e9s<br \/>\n-21\u00b0C pour les chambres <br><br><\/p>\n<p>Temp\u00e9rature des postes &#8211; installation positive :<br \/>\n+4\u00b0C pour les meubles frigorifiques de vente verticaux ouverts<br \/>\n+2\u00b0C pour les chambres <br><br><\/p>\n<p>NB :<br \/>\nLes relev\u00e9s de fonctionnement de la centrale n\u00b01 n&#8217;\u00e9taient pas possible au moment de l&#8217;intervention sur site car celle-ci n&#8217;\u00e9tait pas encore raccord\u00e9e aux meubles de vente.<br \/>\nLes relev\u00e9s de la centrale num\u00e9ro 2 ont \u00e9t\u00e9 r\u00e9alis\u00e9s apr\u00e8s mis en service des couloirs.<br \/>\nLes relev\u00e9s de la centrale n\u00e9gative sont r\u00e9alis\u00e9s en r\u00e9gime stationnaire avec un seul compresseur en service. <br><br><\/p>\n<div><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsCase_studiesleclerc2.jpg\" alt=\"\" width=\"500\" height=\"329\" border=\"0\" \/><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dans le cadre de l&#8217;agrandissement de l&#8217;hypermarch\u00e9 Leclerc \u00e0 Querqueville, la soci\u00e9t\u00e9 Gouville Froid SAS s&#8217;est vue confier la conception et l&#8217;installation frigorifique du projet de r\u00e9novation.<\/p>\n","protected":false},"author":53,"featured_media":140866,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9155],"tags":[],"product_cat":[],"class_list":["post-155180","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-etudes-de-cas"],"_links":{"self":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/comments?post=155180"}],"version-history":[{"count":9,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155180\/revisions"}],"predecessor-version":[{"id":195593,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155180\/revisions\/195593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/media\/140866"}],"wp:attachment":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/media?parent=155180"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/categories?post=155180"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/tags?post=155180"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/product_cat?post=155180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}