{"id":155554,"date":"2010-04-29T19:28:21","date_gmt":"2010-04-29T19:28:21","guid":{"rendered":"http:\/\/climalife.com\/reconversion-dun-groupe-deau-glacee-de-12-mw-dans-le-quartier-de-lopera-a-paris\/"},"modified":"2023-05-25T09:55:54","modified_gmt":"2023-05-25T09:55:54","slug":"reconversion-dun-groupe-deau-glacee-de-12-mw-dans-le-quartier-de-lopera-a-paris","status":"publish","type":"post","link":"https:\/\/climalife.com\/fr\/reconversion-dun-groupe-deau-glacee-de-12-mw-dans-le-quartier-de-lopera-a-paris\/","title":{"rendered":"Reconversion d\u2019un groupe d\u2019eau glac\u00e9e de 1,2 MW dans le quartier de l\u2019Op\u00e9ra \u00e0 Paris"},"content":{"rendered":"<p>Une reconversion rondement men\u00e9e qui s\u2019inscrit dans la politique environnementale d\u2019Icade Eurogem.<br \/>\nIcade Eurogem et son d\u00e9partement Facility Management, sont en charge de la gestion de l\u2019immeuble Antin Op\u00e9ra situ\u00e9 au 66 rue d\u2019Antin \u00e0 Paris.<br><br><\/p>\n<p>Soucieux d\u2019aborder l\u2019avenir sereinement dans le cadre de sa politique environnementale, Monsieur Bakkti, Manager du site, s\u2019est rapproch\u00e9 de Parabis Froid Industriel pour la reconversion de son installation eau glac\u00e9e qui assure le confort de cet immeuble. Le groupe d\u2019eau glac\u00e9e Climaveneta est compos\u00e9 de trois circuits, comprenant chacun un compresseur \u00e0 piston Refcomp (8 cylindres) d\u2019une puissance frigorifi que unitaire de 400 kW soit une unit\u00e9 totale de 1,2 MW.D\u00e9but 2008, Parabis Froid Industriel, repr\u00e9sent\u00e9 par Monsieur Aub\u00e9ri Lecat, sensibilise son client Icade Eurogem sur les risques de p\u00e9nurie de R-22 et propose une reconversion en 3 temps afi n de ne pas engendrer de g\u00eane vis-\u00e0-vis des occupants de l\u2019immeuble et d\u2019\u00e9taler les co\u00fbts de ce r\u00e9trofi t. Icade Eurogem accepte cette proposition, \u00ab Agir d\u00e8s maintenant permet de limiter les risques en cas de fuite sur l\u2019installation \u00bb comme le souligne Monsieur Bakkti. La premi\u00e8re reconversion a eu lieu en septembre 2008 sur le circuit N\u00b03, la seconde en juin 2009 et la derni\u00e8re est programm\u00e9e pour d\u00e9but 2010. Revenons sur la m\u00e9thodologie de ce r\u00e9trofit. <br><br><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casCapture-5.jpg\" alt=\"\" width=\"271\" height=\"150\" align=\"right\" border=\"0\" hspace=\"5\" vspace=\"15\" \/><\/p>\n<br><br><br><br>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2>Une proc\u00e9dure de reconversion en 4 phases :<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casphasen.png\" alt=\"\" width=\"36\" height=\"35\" align=\"left\" border=\"0\" hspace=\"5\" \/>La soci\u00e9t\u00e9 Parabis Froid Industriel effectue un relev\u00e9 complet de l\u2019installation pour d\u00e9terminer les performances puis r\u00e9alise un diagnostic p\u00e9riodique d\u2019huile (DPH A). Comme le souligne Aub\u00e9ri Lecat \u00ab J\u2019explique aux clients que le pr\u00e9l\u00e8vement de l\u2019huile c\u2019est essentiel, cela va nous r\u00e9v\u00e9ler si l\u2019installation est en bon \u00e9tat, c\u2019est comme une prise de sang pr\u00e9op\u00e9ratoire\u00bb. Une recherche de fuite approfondie est effectu\u00e9e en parall\u00e8le et permet d\u2019anticiper toutes r\u00e9parations \u00e9ventuelles. A ce stade, l\u2019ensemble des donn\u00e9es transmise \u00e0 Climalife pour une mod\u00e9lisation thermodynamique du syst\u00e8me afin de d\u00e9terminer le fluide le plus appropri\u00e9. Le R-427A sera retenu pour ses performances \u00e9nerg\u00e9tiques et frigorifiques. <br><br><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casphasen2.png\" alt=\"\" width=\"36\" height=\"36\" align=\"left\" border=\"0\" hspace=\"5\" \/>Jo\u00ebl Poiret, technicien frigoriste chez Parabis proc\u00e8de \u00e0 la mise en s\u00e9curit\u00e9 de l\u2019installation et r\u00e9cup\u00e8re la charge de fluide de R-22 dans des bouteilles de transfert. Le compresseur est vidang\u00e9 puis est ouvert afin de proc\u00e9der \u00e0 une r\u00e9vision m\u00e9canique (remplacement des pi\u00e8ces d\u2019usure, des clapets, des ressorts et des joints n\u00e9opr\u00e8nes identifi \u00e9s). Les 4 cartouches du d\u00e9shydrateur sont remplac\u00e9es, le compresseur est recharg\u00e9 de 20 litres d\u2019huile polyolester MOBIL EAL Arctic 68, puis l\u2019installation est tir\u00e9e au vide. Afi n de bien ramener un maximum de l\u2019huile min\u00e9rale r\u00e9siduelle contenue dans le circuit, la charge de 52 kg de R-22 est r\u00e9int\u00e9gr\u00e9e dans l\u2019installation pendant 24 \u00e0 30 heures de fonctionnement effectif.Un relev\u00e9 des compteurs est effectu\u00e9. <br><br><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casphasen3.png\" alt=\"\" width=\"36\" height=\"36\" align=\"left\" border=\"0\" hspace=\"5\" \/> L\u2019installation est \u00e0 nouveau mise en s\u00e9curit\u00e9, on r\u00e9cup\u00e8re le R-22 dans des bouteilles de r\u00e9cup\u00e9ration, la quantit\u00e9 est pes\u00e9e. Le R-22 r\u00e9cup\u00e9r\u00e9 est transf\u00e9r\u00e9 chez Climalife pour retraitement accompagn\u00e9 du Bordereau de Suivi des D\u00e9chets d\u00fbment rempli. La charge en huile du compresseur est renouvel\u00e9e et on change les cartouches du d\u00e9shydrateur une seconde fois. Apr\u00e8s un tirage au vide, le fluide de substitution R-427A est charg\u00e9 \u00e0 hauteur de 95% de la charge nominale de l\u2019installation, soit 50 kg. <br><br><\/p>\n<p>L\u2019installation peut de nouveau fonctionner, seul un r\u00e9glage du d\u00e9tendeur est effectu\u00e9. Une recherche de fuite minutieuse est effectu\u00e9e pour s\u2019assurer du confi nement optimal de l\u2019installation ; une \u00e9tiquette est appos\u00e9e sur le syst\u00e8me comme le pr\u00e9voit la r\u00e9glementation en vigueur et un dernier relev\u00e9 est effectu\u00e9 sur la base de celui r\u00e9alis\u00e9 initialement pour comparer les performances. <br><br><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casphasen4.png\" alt=\"\" width=\"36\" height=\"36\" align=\"left\" border=\"0\" hspace=\"5\" \/>Un nouveau pr\u00e9l\u00e8vement d\u2019huile est r\u00e9alis\u00e9 apr\u00e8s quelques jours de fonctionnement avec un DPHE, produit de Climalife. Celui-ci permet de diagnostiquer le r\u00e9siduel d\u2019huile d\u2019origine apr\u00e8s le r\u00e9trofit. Pour Aub\u00e9ri Lecat, \u00ab cette ultime \u00e9tape est d\u00e9terminante pour s\u2019assurer que tout fonctionne, cela nous permet notamment de savoir s\u2019il faudra de nouveau vidanger ou pas \u00bb. Au final, l\u2019op\u00e9ration de reconversion est un v\u00e9ritable succ\u00e8s, tant au niveau de la proc\u00e9dure de mise en oeuvre que des performances obtenues.<br \/>\nLa perte de puissance est tr\u00e8s proche du r\u00e9sultat pr\u00e9vu initialement par les \u00e9tudes th\u00e9oriques. Cette diff\u00e9rence de 1% est due au r\u00e9gime d\u2019eau glac\u00e9e du R-427A qui est inf\u00e9rieur \u00e0 celui du R-22.<br><br><\/p>\n<br><br>\n<p><!-- [if gte mso 9]><xml>     Normal   0   21         false   false   false                             MicrosoftInternetExplorer4   <\/xml><![endif]--><!-- [if gte mso 9]><xml>     <\/xml><![endif]--> <!-- [if gte mso 10]> \n\n\n\n<style>  \/* Style Definitions *\/  table.MsoNormalTable \t{mso-style-name:\"Normale Tabelle\"; \tmso-tstyle-rowband-size:0; \tmso-tstyle-colband-size:0; \tmso-style-noshow:yes; \tmso-style-parent:\"\"; \tmso-padding-alt:0cm 5.4pt 0cm 5.4pt; \tmso-para-margin:0cm; \tmso-para-margin-bottom:.0001pt; \tmso-pagination:widow-orphan; \tfont-size:10.0pt; \tfont-family:\"Times New Roman\"; \tmso-ansi-language:#0400; \tmso-fareast-language:#0400; \tmso-bidi-language:#0400;} table.MsoTableGrid \t{mso-style-name:Tabellengitternetz; \tmso-tstyle-rowband-size:0; \tmso-tstyle-colband-size:0; \tborder:solid windowtext 1.0pt; \tmso-border-alt:solid windowtext .5pt; \tmso-padding-alt:0cm 5.4pt 0cm 5.4pt; \tmso-border-insideh:.5pt solid windowtext; \tmso-border-insidev:.5pt solid windowtext; \tmso-para-margin:0cm; \tmso-para-margin-bottom:.0001pt; \tmso-pagination:widow-orphan; \tfont-size:10.0pt; \tfont-family:\"Times New Roman\"; \tmso-fareast-font-family:\"MS Mincho\"; \tmso-ansi-language:DE-AT; \tmso-fareast-language:JA;} <\/style>\n\n\n\n <![endif]--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"311\"><\/td>\n<td valign=\"top\" width=\"72\"><\/td>\n<td colspan=\"2\" valign=\"top\" width=\"167\">\n<p align=\"center\"><strong>Etude th\u00e9orique<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"168\">\n<p align=\"center\"><strong>Relev\u00e9s sur site<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\"><\/td>\n<td valign=\"top\" width=\"72\">Unit\u00e9s<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\"><strong>R-22<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\"><strong>R-427A<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\"><strong>R-22<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\"><strong>R-427A<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Pression moyenne d\u00b4\u00e9vaporation<\/td>\n<td valign=\"top\" width=\"72\">bar<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">4,4<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">4,3<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">4,8<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">4,4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Temp\u00e9rature moyenne d\u00b4\u00e9vaporation<\/td>\n<td valign=\"top\" width=\"72\">\u00b0C<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">-3,5<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">-3,5<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">-3,5<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">-3,5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Pression moyenne de condensation<\/td>\n<td valign=\"top\" width=\"72\">bar<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">15,3<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">15,9<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">15,3<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">16,3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Temp\u00e9rature moyenne de condensation<\/td>\n<td valign=\"top\" width=\"72\">\u00b0C<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">40<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">40<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">40<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Temp\u00e9rature de refoulement<\/td>\n<td valign=\"top\" width=\"72\">\u00b0C<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">75,2<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">65,7<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">76<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">56,7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Puissance frigorifique<\/td>\n<td valign=\"top\" width=\"72\">kW<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">354<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">326<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">358<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">326<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Puissance de compression<\/td>\n<td valign=\"top\" width=\"72\">kW<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">80,1<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">78,8<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">65<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">60<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Puissance condensateur<\/td>\n<td valign=\"top\" width=\"72\">kW<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">434<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">406<\/p>\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">439<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">406<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">R\u00e9gime eau glac\u00e9e<\/td>\n<td valign=\"top\" width=\"72\">\u00b0C<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">10,5\/9,6<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">9,3\/8,2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Perte puissance<\/td>\n<td valign=\"top\" width=\"72\">%<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"167\">\n<p align=\"center\">&#8211; 7,9<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"168\">\n<p align=\"center\">&#8211; 9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"311\">Charge en fluide<\/td>\n<td valign=\"top\" width=\"72\">kg<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">\n<\/td>\n<td valign=\"top\" width=\"80\">\n<p align=\"center\">52<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">50<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<br><br>\n<p><span class=\"bleu\"><strong>Soci\u00e9t\u00e9 :<\/strong> PARABIS FROID INDUSTRIEL<br \/>\n<strong>Activit\u00e9 :<\/strong> Froid industriel et climatisation<br \/>\n<strong>Localisation :<\/strong> La Courneuve (93) &#8211; France<br \/>\n<strong>Date de cr\u00e9ation :<\/strong> 1974<br \/>\n<strong>Effectif :<\/strong> 6<\/span><\/p>\n<p>Date: Juin 2009<\/p>\n<p>Auteur: D. Martin<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conscient du risque de p\u00e9nurie du R-22 \u00e0 compter de 2010, Parabis Froid Industriel informe son client des enjeux et pr\u00e9conise en trois \u00e9tapes la reconversion au R-427A du groupe d\u2019eau glac\u00e9e alimentant un immeuble de bureaux de standing d\u2019une surface de 10 000 m\u00b2.<\/p>\n","protected":false},"author":53,"featured_media":141199,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9155],"tags":[],"product_cat":[],"class_list":["post-155554","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-etudes-de-cas"],"_links":{"self":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/comments?post=155554"}],"version-history":[{"count":12,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155554\/revisions"}],"predecessor-version":[{"id":199603,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/posts\/155554\/revisions\/199603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/media\/141199"}],"wp:attachment":[{"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/media?parent=155554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/categories?post=155554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/tags?post=155554"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/climalife.com\/fr\/wp-json\/wp\/v2\/product_cat?post=155554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}