{"id":155458,"date":"2010-04-29T19:28:21","date_gmt":"2010-04-29T19:28:21","guid":{"rendered":"http:\/\/climalife.com\/leonidas-kiest-voor-forane-427a-ter-vervanging-van-r-22\/"},"modified":"2023-05-25T09:46:49","modified_gmt":"2023-05-25T09:46:49","slug":"leonidas-kiest-voor-forane-427a-ter-vervanging-van-r-22","status":"publish","type":"post","link":"https:\/\/climalife.com\/nl\/leonidas-kiest-voor-forane-427a-ter-vervanging-van-r-22\/","title":{"rendered":"Leonidas kiest voor Forane\u00ae 427A ter vervanging van R-22"},"content":{"rendered":"<p align=\"justify\"><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casvitrine_chocolat.jpg\" alt=\"\" width=\"255\" height=\"353\" align=\"right\" border=\"0\" hspace=\"10\" \/><\/strong><\/p>\n<p align=\"justify\">In maart van dit jaar besloot de heer Pollin, Technisch verantwoordelijke in de Leonidas fabriek in Anderlecht (Belgi\u00eb), de defecte compressor in het koelsysteem te vervangen door een HFK-compressor. De productie van R-22 stopt immers eind 2009.Na een voorstelling van de vervangmiddelen van R-22 en op technisch advies van Climalife, koos Leonidas voor Forane\u00ae 427A. De prestaties van dit HFK-mengsel leunen immers dicht aan bij die van R-22.<br \/>\nDe originele installatie dateert van 1987 en bevat een halfhermetische Frascold compressor van 15 pk met een koelvermogen van 35 kW.<\/p>\n<p align=\"justify\"><strong>Leonidas<\/strong>, de wereldvermaarde Belgische chocolatier, schakelt de koelinstallatie van de eindtunnel in de chocolade productielijn om op <strong>Forane\u00ae 427A<\/strong>.<\/p>\n<p>In maart van dit jaar besloot de heer Pollin, Technisch verantwoordelijke in de Leonidas fabriek in Anderlecht (Belgi\u00eb), de defecte compressor in het koelsysteem te vervangen door een HFK-compressor. De productie van R-22 stopt immers eind 2009.<\/p>\n<p>Na een voorstelling van de vervangmiddelen van R-22 en op <strong>technisch advies van Climalife<\/strong>, koos Leonidas voor <strong>Forane\u00ae 427A<\/strong>. De prestaties van dit HFK-mengsel leunen immers dicht aan bij die van R-22.<\/p>\n<p>De originele installatie dateert van 1987 en bevat een halfhermetische Frascold compressor van 15 pk met een koelvermogen van 35 kW.<\/p>\n<p align=\"justify\">Om de chocoladeproductie niet te onderbreken, schakelden de heren Bouazza en Ismali, Koeltechnici, de productie over op een polyvalente lijn gedurende hun tussenkomst.<\/p>\n<p>Eerst werd de R-22 uit de installatie gerecupereerd en vervolgens werd deze vacu\u00fcm getrokken. De reiniging van de installatie bleek niet nodig.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casM3_-_FAG_003web.jpg\" alt=\"\" width=\"250\" height=\"333\" align=\"left\" border=\"0\" hspace=\"10\" \/>Vervolgens plaatsten ze de nieuwe Frascold compressor, voorgevuld met POE olie. De olie wordt binnenkort ververst om eventuele restolie te verwijderen. Ze vervingen eveneens de filterdrogers en het kijkglas en brachten 30 kg <strong>Forane\u00ae 427A <\/strong>in de installatie in via een fles van 61 liter.<\/p>\n<p>De reduceerklep werd niet vervangen, maar de oververhitting functie werd opnieuw ingesteld om de temperatuurverschuiving van de nieuwe vloeistof <strong>Forane\u00ae 427A<\/strong> (mengsel) te compenseren en een identiek koelrendement te behouden. In een laatste fase controleerden de technici de hoge druk \/ lage druk veiligheidsinrichtingen alvorens de installatie opnieuw in gebruik te nemen.<\/p>\n<p>De gerecupereerde 34 kg R-22<strong> werd aan Climalife bezorgd voor verwerking<\/strong>.<\/p>\n<br>\n<h2>Koude batterij en ventilatiekast<\/h2>\n<p align=\"justify\"><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_casM3_-_FAG_004web.jpg\" alt=\"\" width=\"250\" height=\"203\" align=\"left\" border=\"0\" hspace=\"10\" \/><\/p>\n<p>De operatie was een groot succes. Het Leonidas team was zeer tevreden en zal de <strong>29 andere koelinstallaties van de productielijn tegen eind 2009 eveneens omschakelen op Forane\u00ae 427A<\/strong> omwille van zijn milieubeleid.<\/p>\n<p class=\"bleu\">\n<br><br><br><br>\n<h2 class=\"bleu\">Vergelijkende resultaten R-22 \/ Forane\u00ae 427A<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"263\"><\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">Eenheden<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">R-22<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">Forane<sup>\u00ae<\/sup> 427A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Vulgewicht installatie<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">kg<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">34<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Verdampingstemperatuur<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">&#8211; 4<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">&#8211; 4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Verdampingsdruk<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">bar<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">3,4<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">3,6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Luchttemperatuur op de uitgang van de tunnel<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Condensatietemperatuur<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">\u00b0C<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">44<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Condensatiedruk<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">bar<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">15,8<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">15<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"263\">Koelvermogen<\/td>\n<td valign=\"top\" width=\"92\">\n<p align=\"center\">kW<\/p>\n<\/td>\n<td valign=\"top\" width=\"100\">\n<p align=\"center\">35<\/p>\n<\/td>\n<td valign=\"top\" width=\"112\">\n<p align=\"center\">35<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<br>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsEtudes_de_caslogo_Leonidas.jpg\" alt=\"\" width=\"356\" height=\"71\" align=\"right\" border=\"0\" \/><\/p>\n<p><strong>Auteur <\/strong>: Delphine Martin<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Leonidas, de wereldvermaarde Belgische chocolatier, schakelt de koelinstallatie van de eindtunnel in de chocolade productielijn om op Forane\u00ae 427A.<\/p>\n","protected":false},"author":36,"featured_media":136827,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9158],"tags":[],"product_cat":[],"class_list":["post-155458","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-casestudys"],"_links":{"self":[{"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/posts\/155458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/users\/36"}],"replies":[{"embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/comments?post=155458"}],"version-history":[{"count":9,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/posts\/155458\/revisions"}],"predecessor-version":[{"id":199587,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/posts\/155458\/revisions\/199587"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/media\/136827"}],"wp:attachment":[{"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/media?parent=155458"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/categories?post=155458"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/tags?post=155458"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/climalife.com\/nl\/wp-json\/wp\/v2\/product_cat?post=155458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}