{"id":159483,"date":"2021-07-15T12:48:25","date_gmt":"2021-07-15T12:48:25","guid":{"rendered":"http:\/\/climalife.com\/leak-detection-for-refrigeration-systems-a-major-challenge-for-the-21st-century\/"},"modified":"2025-11-07T10:01:50","modified_gmt":"2025-11-07T10:01:50","slug":"leak-detection-for-refrigeration-systems-a-major-challenge-for-the-21st-century","status":"publish","type":"post","link":"https:\/\/climalife.com\/ro\/leak-detection-for-refrigeration-systems-a-major-challenge-for-the-21st-century\/","title":{"rendered":"Detectarea scurgerilor \u00een sistemele de refrigerare: o provocare major\u0103 pentru secolul XXI"},"content":{"rendered":"<h2><strong>1) Reglement\u0103ri<\/strong><\/h2>\n<p>Reglementarea stabile\u0219te, de asemenea, cerin\u021be de formare, interdic\u021bii de utilizare \u0219i interdic\u021bii de introducere pe pia\u021b\u0103 \u00een func\u021bie de GWP (poten\u021bialul de \u00eenc\u0103lzire global\u0103) \u0219i de aplica\u021bie, reduceri ale cantit\u0103\u021bilor produse (cote) \u0219i cerin\u021be: calificare, echipamente obligatorii \u0219i prevenirea emisiilor, cu obliga\u021bia de a efectua verific\u0103ri ale scurgerilor la instala\u021biile care con\u021bin gaze fluorurate cu efect de ser\u0103.<\/p>\n<h3><strong>Sec\u021biunea specific\u0103 privind F-Gaze referitoare la verificarea scurgerilor:<\/strong><\/h3>\n<p>Capitolul II articolul 4 din Regulamentul (UE) nr. 517-2014 specific\u0103 frecven\u021ba verific\u0103rilor \u00een func\u021bie de \u00eenc\u0103rcarea \u00een tone de CO2 echivalent a instala\u021biilor.<\/p>\n<p><strong>\u00cenc\u0103rcare \u2265 5 t de CO2 echivalent:<\/strong> cel pu\u021bin o dat\u0103 la 12 luni sau numai o dat\u0103 la 24 de luni dac\u0103 sunt echipate cu un detector de scurgeri fix.<\/p>\n<p><strong>\u00cenc\u0103rcare \u2265 50 t de CO2 echivalent:<\/strong> cel pu\u021bin o dat\u0103 la \u0219ase luni sau numai o dat\u0103 la 12 luni dac\u0103 instala\u021bia este echipat\u0103 cu un detector fix de scurgeri.<\/p>\n<p><strong>\u00cenc\u0103rcare \u2265 500 t de CO2 echivalent:<\/strong> cel pu\u021bin o dat\u0103 la trei luni sau numai o dat\u0103 la \u0219ase luni dac\u0103 instala\u021bia este echipat\u0103 cu un detector fix de scurgeri.<\/p>\n<p>Operatorii sunt obliga\u021bi s\u0103 instaleze un detector fix de scurgeri care s\u0103 alerteze operatorul sau compania de \u00eentre\u021binere \u00een cazul unei scurgeri pentru instala\u021biile cu o \u00eenc\u0103rc\u0103tur\u0103 de agent frigorific egal\u0103 sau mai mare de 500 t de CO<sub>2<\/sub> echivalent (de exemplu, 128 kg de R-404A).<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Pentru sisteme sta\u021bionare (refrigerare, climatizare, pompe de c\u0103ldur\u0103, stingerea incendiilor)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Pentru ma\u0219ini cu ciclu Rankine \u0219i aparate de comutare electric\u0103 instalate dup\u0103 01\/01\/2017<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articletableau20charge20refrigerant.png\" alt=\"tableau charge fluides\" width=\"1206\" height=\"300\" \/><\/p>\n<p>Pentru statele membre ale Uniunii Europene, pe l\u00e2ng\u0103 Regulamentul privind gazele fluorurate, pot exista reglement\u0103ri na\u021bionale mai stricte.<\/p>\n<h2><strong>2) Detectarea scurgerilor conform standardului EN 378:<br \/>\n<\/strong><\/h2>\n<p>\u00cen plus fa\u021b\u0103 de reglement\u0103rile de mediu, standardul european EN 378 ofer\u0103 un supliment pentru a asigura siguran\u021ba persoanelor.<\/p>\n<p>Acesta prevede c\u0103 s\u0103lile de ma\u0219ini trebuie s\u0103 fie echipate cu detectoare pentru a asigura siguran\u021ba tuturor utilizatorilor.<\/p>\n<p>Pentru gazele explozive sau periculoase, pragul de detectare este stabilit la mai pu\u021bin de 20% din limita inferioar\u0103 de inflamabilitate, iar detectoarele de amoniac trebuie s\u0103 declan\u0219eze ventilarea, o alarm\u0103 \u0219i s\u0103 deconecteze alimentarea extern\u0103 cu energie electric\u0103.<\/p>\n<h2><strong>3) Tipuri de detectare: detectare direct\u0103 (detectoare portabile; detectoare fixe de scurgeri) \u0219i detectare indirect\u0103 (monitorizare continu\u0103 prin intermediul unui sistem expert)<\/strong><\/h2>\n<p>Exist\u0103 mai multe tipuri de detectare:<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>\u00cen primul r\u00e2nd, <strong>metodele directe<\/strong> permit verificarea scurgerilor la fa\u021ba locului \u0219i sunt utilizate pentru verific\u0103ri periodice (detectoare portabile) sau continue (detectoare fixe de scurgeri). Detectoarele portabile pot fi utilizate pentru localizarea scurgerii.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>\u00cen plus fa\u021b\u0103 de aceast\u0103 metod\u0103 \u0219i pentru a permite monitorizarea complet\u0103 a func\u021bion\u0103rii instala\u021biei, au fost dezvoltate <strong>metode indirecte<\/strong>. Utilizarea senzorilor care efectueaz\u0103 m\u0103sur\u0103tori regulate \u00eempreun\u0103 cu calcule algoritmice permite amplasarea acestui tip de dispozitiv \u00een interiorul instala\u021biei pentru a identifica \u0219i monitoriza comportamentul acesteia.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong>Pentru a respecta Regulamentul privind gazele fluorurate, inspec\u021bia fizic\u0103 a instala\u021biei trebuie efectuat\u0103 cu un detector portabil. <\/strong>Conform prevederilor Regulamentului european 517-2014, frecven\u021ba verific\u0103rilor poate fi redus\u0103<a href=\"\/technical-file\/42\/translate\/en\/ro#_ftn1\" name=\"_ftnref1\">[1]<\/a> dac\u0103 instala\u021biile sunt echipate cu <strong>un detector de scurgeri fix sau un sistem bazat pe metode de m\u0103surare indirect\u0103<\/strong>.<\/p>\n<p>Astfel, pentru a reduce frecven\u021ba inspec\u021biilor fizice, este posibil\u0103 utilizarea sistemelor de detectare sta\u021bionare, cunoscute sub denumirea de \u201edetector fix de scurgeri\u201d sau \u201esistem de detectare sta\u021bionar\u201d, \u0219i a sistemelor de detectare cu m\u0103surare indirect\u0103 instalate pe unitatea de r\u0103cire, care permit <strong>monitorizarea continu\u0103 a instala\u021biilor \u0219i declan\u0219area unei alerte \u00een cazul apari\u021biei unei scurgeri<\/strong>.<\/p>\n<p>Unele \u021b\u0103ri, precum Fran\u021ba \u0219i Belgia, au adoptat posibilitatea verific\u0103rii indirecte a scurgerilor cu sisteme de detectare indirect\u0103 monitorizate continuu (a se vedea sec\u021biunea 5).<\/p>\n<p>Astfel, cele trei metode de detectare a scurgerilor sunt complementare: ele garanteaz\u0103 conformitatea cu Regulamentul F-Gas 2, contribuind la reducerea scurgerilor \u0219i, prin urmare, la protejarea mediului, garant\u00e2nd \u00een acela\u0219i timp siguran\u021ba persoanelor.<\/p>\n<h2><strong>4) Tehnologia senzorilor<br \/>\n<\/strong><\/h2>\n<p>Exist\u0103 trei forme de tehnologie a senzorilor: semiconductori (sau senzori cu diode \u00eenc\u0103lzite), senzori electrochimici \u0219i senzori cu infraro\u0219u. Alegerea senzorului depinde de gazele sau fluidele care trebuie detectate.<\/p>\n<h3><strong>a) Senzori semiconductori: pentru HFO, HFC, CFC, HCFC<\/strong><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlecapteurs20semi20conducteurs.png\" alt=\"\" width=\"325\" height=\"158\" \/><\/p>\n<p>Aceast\u0103 tehnologie are avantajul de a fi cea mai ieftin\u0103. Cu toate acestea, este sensibil\u0103 la temperatura ambiant\u0103, umiditate, solven\u021bi, agen\u021bi de cur\u0103\u021bare, HC (propan) \u0219i NOx (oxizi de azot).<\/p>\n<p><em><sup>1<\/sup> A se vedea tabelul de la pagina 1<br \/>\n<\/em><\/p>\n<p><em>Senzorul semiconductor, cunoscut \u0219i sub denumirea de senzor de oxid metalic (MOS), detecteaz\u0103 produsele toxice, combustibilii \u0219i agen\u021bii frigorifici. Este sensibil la modific\u0103rile concentra\u021biei de gaz (sc\u0103derea concentra\u021biei de oxigen), umiditate \u0219i schimb\u0103rile de temperatur\u0103. Sensibilitatea sa este redus\u0103 \u0219i trebuie calibrat. Este o tehnologie economic\u0103, cu o durat\u0103 de via\u021b\u0103 lung\u0103 (aproximativ cinci ani). <\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlebacharach.png\" alt=\"\" width=\"300\" height=\"181\" \/><\/p>\n<p><em>copyright bacharach<\/em><\/p>\n<p><em> <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articledetection.png\" alt=\"\" width=\"350\" height=\"160\" \/><\/em>Principiul de detectare: un film sub\u021bire de oxid metalic este depus pe o suprafa\u021b\u0103 de silicon. Reac\u021bia catalitic\u0103 de oxidare \u00een contact cu gazul \u021bint\u0103 \u0219i suprafa\u021ba \u00eenc\u0103lzit\u0103 de oxid metalic modific\u0103 rezisten\u021ba electric\u0103 \u0219i alter\u0103 conductivitatea. Aceast\u0103 modificare a rezisten\u021bei este corelat\u0103 cu concentra\u021bia de gaz m\u0103surat\u0103.<\/p>\n<h3><strong>b) Senzori electrochimici: NH<sub>3<\/sub><\/strong><\/h3>\n<p>Aceast\u0103 tehnologie de senzori este utilizat\u0103 pentru detectarea NH<sub>3<\/sub>. Este o tehnologie ultraprecis\u0103, care asigur\u0103 siguran\u021ba persoanelor datorit\u0103 detect\u0103rii la concentra\u021bii sc\u0103zute ale acestui produs toxic.<\/p>\n<p><em><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlecapteurs20electro20chimiques.png\" alt=\"\" width=\"197\" height=\"168\" \/><\/em><\/p>\n<p><em>Aceast\u0103 tehnologie de senzori este utilizat\u0103 pentru detectarea NH<sub>3<\/sub>. Este o tehnologie extrem de precis\u0103, care asigur\u0103 siguran\u021ba persoanelor datorit\u0103 detect\u0103rii concentra\u021biilor sc\u0103zute ale acestui produs toxic. <\/em><\/p>\n<p><em>Aceast\u0103 tehnologie este potrivit\u0103 pentru o gam\u0103 larg\u0103 de gaze toxice \u0219i este foarte precis\u0103 la concentra\u021bii foarte sc\u0103zute de ppm. R\u0103spunde rapid la o scurgere \u0219i este o tehnologie selectiv\u0103 care caut\u0103 numai gazul \u021bint\u0103. Prin urmare, nu exist\u0103 riscul de sensibilitate \u00eencruci\u0219at\u0103. Aceast\u0103 tehnologie trebuie calibrat\u0103 \u00een func\u021bie de gazul \u021bint\u0103, iar senzorii au o durat\u0103 de via\u021b\u0103 de trei p\u00e2n\u0103 la cinci ani.<\/em><\/p>\n<p><em><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlecapteur20electro20chimiques202.png\" alt=\"\" width=\"200\" height=\"122\" \/><\/em><\/p>\n<p><em>Senzorul este format dintr-un electrod de lucru, un contraelectrod, un electrod de referin\u021b\u0103 \u0219i un electrolit. Senzorii electrochimici func\u021bioneaz\u0103 ca bateriile. C\u00e2nd gazul \u021bint\u0103 este prezent, o reac\u021bie chimic\u0103 pe electrodul de lucru genereaz\u0103 o mic\u0103 sarcin\u0103 electric\u0103 \u00eentre doi electrozi, propor\u021bional\u0103 cu concentra\u021bia de gaz.<\/em><\/p>\n<h3><strong>c) Senzori cu infraro\u0219u: detectarea HFO, HFC, CFC, HCFC, NH<sub>3<\/sub>, propan, CO<sub>2<\/sub>.<\/strong><\/h3>\n<p>Tehnologia senzorilor infraro\u0219ii este extrem de sensibil\u0103. Poate detecta o gam\u0103 larg\u0103 de agen\u021bi frigorifici, fiind complet insensibil\u0103 la alte produse, \u0219i are o durat\u0103 de via\u021b\u0103 lung\u0103. Poate detecta HFO, HFC, HCFC, CFC, NH<sub>3<\/sub>, propan (R-290) \u0219i CO<sub>2<\/sub>.<\/p>\n<p><em><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlecapteur20infra20rouge.png\" alt=\"\" width=\"250\" height=\"183\" \/><\/em><\/p>\n<p><em>Senzorul cu infraro\u0219u este extrem de sensibil, cu o sensibilitate \u00eencruci\u0219at\u0103 foarte redus\u0103 fa\u021b\u0103 de alte gaze. Aceast\u0103 tehnologie nu este sensibil\u0103 la poluan\u021bi (silicon, plumb etc.) \u0219i se poate calibra automat. Timpii de r\u0103spuns sunt scur\u021bi, cu praguri de detectare posibile la concentra\u021bii foarte sc\u0103zute (sensibilitate de 1 ppm). Este o tehnologie de detectare extrem de precis\u0103, de\u0219i pu\u021bin mai scump\u0103; durata medie de via\u021b\u0103 a senzorului este de cinci p\u00e2n\u0103 la \u0219apte ani.<\/em><\/p>\n<p><em><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlecapteur20dC3A9composition.png\" alt=\"\" width=\"350\" height=\"165\" \/><\/em><\/p>\n<p><em>Senzorul este format dintr-o surs\u0103 de lumin\u0103, un filtru anti-interferen\u021b\u0103, un detector \u0219i o camer\u0103 \u00een care gazul \u021bint\u0103 este difuzat dup\u0103 ce a fost aspirat. Numai culoarea verde a fasciculului de lumin\u0103 este filtrat\u0103 \u0219i analizat\u0103 prin m\u0103surarea intensit\u0103\u021bii sale. Dac\u0103 este prezent un gaz, culoarea verde a radia\u021biei luminoase este redus\u0103 cu o cantitate m\u0103surabil\u0103.<\/em><\/p>\n<h2><strong>5) <\/strong><strong>Dispozitive de detectare \u0219i descrieri<\/strong><\/h2>\n<h3>Detectoare portabile:<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articledetecteurs20portables.jpg\" alt=\"\" width=\"124\" height=\"68\" \/><\/p>\n<p>Scurgerile sunt semnalate printr-o alarm\u0103 sonor\u0103 \u0219i vizual\u0103 \u0219i un ecran de afi\u0219are. Acest tip de detector permite localizarea precis\u0103 a zonei de scurgere.<\/p>\n<p>\u00cenainte de fiecare utilizare, o verificare cu ajutorul unui produs precum mini-check, care simuleaz\u0103 o scurgere calibrat\u0103 de R-134a de 5 g\/an, permite verificarea calibr\u0103rii dispozitivului.<\/p>\n<h3>Detectarea bulelor:<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articledetection20par20bulle.jpg\" alt=\"\" width=\"112\" height=\"149\" \/><\/p>\n<p>Dup\u0103 c\u0103utarea unei scurgeri cu un detector portabil, se poate utiliza un aerosol, cum ar fi Prestobul, pe conductele unde se afl\u0103 scurgerea suspectat\u0103, pentru a identifica sursa prin prezen\u021ba bulelor.<\/p>\n<h3>Detectoare fixe de scurgeri:<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsTechnical20FileLeak20detection20articlebacharach202.png\" alt=\"\" width=\"150\" height=\"150\" \/><\/p>\n<p>Detectorul de scurgeri sta\u021bionar, cunoscut \u0219i sub denumirea de detector de scurgeri fix, este un detector de scurgeri de agent frigorific. \u00cen func\u021bie de model, este un senzor-transmi\u021b\u0103tor independent cu alarme, care poate fi utilizat fie ca detector autonom, fie conectat la un sistem de control (de exemplu, BMS) printr-o leg\u0103tur\u0103 Modbus. Acestea sunt, \u00een general, echipate cu unul sau mai multe relee pentru a activa echipamente de siguran\u021b\u0103 externe, cum ar fi supape, ventilatoare, alarme generale etc. Acestea necesit\u0103 instalarea de senzori, numi\u021bi \u0219i \u201esonde\u201d, \u00een conformitate cu caracteristicile specifice ale instala\u021biilor \u0219i ale fluidelor care trebuie detectate. Acestea trebuie selectate \u0219i adaptate la fluidele care urmeaz\u0103 s\u0103 fie detectate.<\/p>\n<h3>Pozi\u021bionarea senzorilor:<\/h3>\n<p>Proteja\u021bi de stropi de ap\u0103 \u0219i de poten\u021biale pericole, departe de zone cu curen\u021bi de aer sau ventilate (zone cu trafic intens \u0219i flux de aer puternic, zone de extrac\u021bie (ventilator)) \u0219i departe de sisteme de identificare prin radiofrecven\u021b\u0103 sau de transmi\u021b\u0103toare pentru aceste sisteme.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsB20image201.jpg\" alt=\"\" width=\"750\" height=\"433\" \/><\/p>\n<p>\u00cen interesul siguran\u021bei umane, pozi\u021biona\u021bi senzorii \u00een zona de locuit (oxigenare).<\/p>\n<p><strong>Predictiv integrat &#8211; DNI: autoriza\u021bie belgian\u0103 + eficien\u021b\u0103 energetic\u0103<\/strong><\/p>\n<p>Cu rate medii de scurgere de aproximativ 20% p\u00e2n\u0103 la 25% pe an, unit\u0103\u021bile de condensare instalate \u00een magazinele alimentare sau \u00een industria alimentar\u0103 necesit\u0103 detectoare de scurgeri permanente pentru continuitatea proceselor, pentru a \u00eembun\u0103t\u0103\u021bi performan\u021ba \u0219i a respecta reglement\u0103rile de mediu.<\/p>\n<p>Detectorul inteligent de nivel Matelex (\u201eDNI\u201d &#8211; Detector inteligent de nivel) este un detector de scurgeri fix, brevetat, bazat pe metoda de m\u0103surare indirect\u0103. Aceast\u0103 metod\u0103 implic\u0103 analiza continu\u0103 a parametrilor de func\u021bionare ai instala\u021biei. DNI, prin intermediul unui algoritm specific \u0219i al metrologiei asociate, \u00eenva\u021b\u0103 a\u0219a-numita func\u021bionare \u201enormal\u0103\u201d a unei instala\u021bii datorit\u0103 analizei permanente a func\u021bion\u0103rii acesteia. Apoi identific\u0103 abaterile de la aceast\u0103 func\u021bionare \u0219i este astfel capabil s\u0103 detecteze prezen\u021ba unei scurgeri.<\/p>\n<p>DNI, compatibil cu 120 de fluide \u0219i diferite tipuri de rezervoare HP (verticale, orizontale, \u00eenclinate), utilizeaz\u0103 principiul vaselor comunicante pentru a m\u0103sura nivelul fluidului din rezervor f\u0103r\u0103 a fi necesare modific\u0103ri majore ale instala\u021biei. O coloan\u0103 de cupru de 1&#8243; 5\/8, adaptat\u0103 la geometria rezervorului, este c\u00e2nt\u0103rit\u0103 cu un extensometru. Protejarea acestei coloane va permite instalarea acestui tip de metod\u0103 \u00een exterior.<\/p>\n<p>Analiza \u00een timp real a datelor metrologice colectate privind greutatea\/presiunea\/temperatura \u0219i luarea \u00een considerare a datelor termodinamice ale fluidului utilizat vor indica prezen\u021ba scurgerilor la nivel local (contact uscat pe BMS) sau la distan\u021b\u0103 (monitorizare online Sentinelle, alerte prin e-mail). Scopul monitoriz\u0103rii continue este, prin urmare, detectarea timpurie a scurgerilor, permi\u021b\u00e2nd operatorilor s\u0103 reac\u021bioneze mai rapid.<\/p>\n<p>Pentru a asigura precizia m\u0103sur\u0103torilor, se efectueaz\u0103 o verificare anual\u0103 pentru a \u00eenlocui lan\u021bul de m\u0103surare a greut\u0103\u021bii\/presiunii \u0219i a calibra sondele de temperatur\u0103, astfel \u00eenc\u00e2t s\u0103 se poat\u0103 lua \u00een considerare impedan\u021ba cablurilor \u0219i deriva sondelor PT100.<\/p>\n<p>Exist\u0103 dou\u0103 tipuri de alarme, care permit monitorizarea continu\u0103 \u0219i feedback-ul esen\u021bial pentru func\u021bionarea unui proces de refrigerare.<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Alarm\u0103 de nivel sc\u0103zut: similar\u0103 nivelurilor sta\u021bionare \u201eKubler\u201d \u00eent\u00e2lnite la un num\u0103r mare de rezervoare, DNI permite monitorizarea continu\u0103 \u0219i configurabil\u0103 a nivelului sc\u0103zut din rezervor. Configura\u021bia sa permite ajustarea pragului de declan\u0219are \u0219i alertarea rapid\u0103 a operatorului \u00een cazul unei sc\u0103deri semnificative \u0219i rapide a nivelului fluidului.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Alarm\u0103 \u201estatistic\u0103\u201d: analiz\u0103 algoritmic\u0103 care necesit\u0103 o perioad\u0103 de \u00eenv\u0103\u021bare pentru a func\u021biona. Perioada de \u00eenv\u0103\u021bare &#8211; \u0219apte zile \u00een care m\u0103sur\u0103torile sunt analizate \u00een mod specific &#8211; permite definirea nivelurilor de referin\u021b\u0103 ale instala\u021biei. Utilizate de algoritmul \u00een timp real, nivelurile de referin\u021b\u0103 sunt comparate cu datele medii pentru a asigura fiabilitatea alarmelor \u201estatistice\u201d \u0219i pentru a adapta analiza \u00een timp real la fiecare unitate de condensare.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Sistemul de monitorizare expert, Sentinelle, afi\u0219eaz\u0103 valorile \u00eenregistrate de DNI sub form\u0103 de curbe detaliate, permi\u021b\u00e2nd o analiz\u0103 vizual\u0103 \u0219i documentat\u0103 a func\u021bion\u0103rii instala\u021biei. Sunt disponibile multe alte evalu\u0103ri cu scopul de a \u00eembun\u0103t\u0103\u021bi performan\u021ba instala\u021biilor \u0219i de a reduce impactul acestora asupra mediului prin reducerea emisiilor directe \u0219i indirecte de gaze cu efect de ser\u0103.<\/p>\n<p>Pe l\u00e2ng\u0103 abordarea impactului direct asupra mediului al unei scurgeri de agent frigorific, Matelex lucreaz\u0103 \u0219i la reducerea impactului indirect al consumului de energie. Analiza efectuat\u0103 de DNI \u0219i Sentinelle permite luarea de m\u0103suri \u00eempotriva consumului excesiv de energie din cauza unui nivel sc\u0103zut de agent frigorific \u00een cilindru.<\/p>\n<p>\u00cen cele din urm\u0103, pe l\u00e2ng\u0103 detectarea scurgerilor, modulul energetic, ad\u0103ugat la DNI, permite determinarea \u00een timp real a ciclului entalpic al instala\u021biei, gra\u021bie unor m\u0103sur\u0103tori suplimentare. Ciclurile de func\u021bionare ale compresorului sunt, de exemplu, studiate pentru a avertiza asupra riscurilor de uzur\u0103 prematur\u0103 care pot duce la defectarea compresorului, dar \u0219i pentru a \u00eembun\u0103t\u0103\u021bi gestionarea compresoarelor (reducerea ciclurilor scurte, monitorizarea frecven\u021belor de pornire etc.).<\/p>\n<p>Accesul la analize detaliate \u0219i istorice are scopul de a ajuta instalatorii s\u0103 \u00eembun\u0103t\u0103\u021beasc\u0103 set\u0103rile instala\u021biilor lor, cu scopul de a optimiza func\u021bionarea instala\u021biilor.<\/p>\n<h2><\/h2>\n<h2><strong>6) Cum s\u0103 v\u0103 asigura\u021bi c\u0103 programul dvs. de detectare are succes <\/strong><\/h2>\n<p><strong><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/2022\/09\/uploadsassetsB20image202.jpg\" alt=\"\" width=\"200\" height=\"287\" \/><\/strong><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Instalarea corect\u0103 a echipamentelor de c\u0103tre instalatori instrui\u021bi \u0219i califica\u021bi.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Service \u0219i \u00eentre\u021binere anual\u0103 a echipamentelor.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Testa\u021bi func\u021bionarea corect\u0103 a dispozitivelor \u0219i seta\u021bi pragurile de alarm\u0103 \u00een mod corespunz\u0103tor (kit de calibrare, aplica\u021bie pentru smartphone) pentru a evita pierderile semnificative de agent frigorific.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Testarea \u0219i calibrarea cu gazul dorit<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Verifica\u021bi dac\u0103 senzorii \u0219i alarmele func\u021bioneaz\u0103.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Calibrarea men\u021bine precizia senzorului. Este obligatorie \u00een fiecare an \u00een unele \u021b\u0103ri europene.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>7) Avantajele detect\u0103rii scurgerilor: <\/strong><\/h2>\n<p>&#8211; Reducerea cantit\u0103\u021bii de fluid utilizat = economii financiare<\/p>\n<p>&#8211; Emisii mai sc\u0103zute de gaze cu efect de ser\u0103 = beneficii pentru mediu<\/p>\n<p>&#8211; Consum redus de energie = economii financiare \u0219i beneficii pentru mediu<\/p>\n<p>&#8211; Performan\u021b\u0103 \u00eembun\u0103t\u0103\u021bit\u0103 a instala\u021biilor datorit\u0103 unei bune etan\u0219\u0103ri \u0219i a unei \u00eenc\u0103rc\u0103ri adecvate cu agent frigorific<\/p>\n<p>&#8211; Respectarea standardelor \u0219i reglement\u0103rilor (EN 378, F-GAS II, ASHRAE etc.) = siguran\u021b\u0103<\/p>\n<p>&#8211; Prevenirea scurgerilor = Protec\u021bia persoanelor \u0219i confort \u00eembun\u0103t\u0103\u021bit = siguran\u021b\u0103 \u0219i s\u0103n\u0103tate<\/p>\n<p>&#8211; Conservarea bunurilor \u0219i echipamentelor = Economii \u0219i siguran\u021b\u0103<\/p>\n<p><em>Acest articol a fost realizat \u00een colaborare de Climalife \u0219i Matelex, doi actori cheie \u00een domeniul performan\u021bei energetice.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Regulamentul (UE) nr. 517\/2014, cunoscut sub denumirea de \u201eF-Gas 2\u201d, a fost adoptat la 16 aprilie 2014 cu scopul de a proteja mediul prin reducerea emisiilor de gaze cu efect de ser\u0103 (GES[LH1] ) cu 80 % p\u00e2n\u0103 la 95 % p\u00e2n\u0103 \u00een 2050, comparativ cu nivelurile din 1990.<\/p>\n","protected":false},"author":36,"featured_media":149289,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13614,9180],"tags":[],"product_cat":[],"class_list":["post-159483","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-detectarea-scurgerilor-ro","category-documente-tehnice"],"_links":{"self":[{"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/posts\/159483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/users\/36"}],"replies":[{"embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/comments?post=159483"}],"version-history":[{"count":12,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/posts\/159483\/revisions"}],"predecessor-version":[{"id":229286,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/posts\/159483\/revisions\/229286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/media\/149289"}],"wp:attachment":[{"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/media?parent=159483"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/categories?post=159483"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/tags?post=159483"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/climalife.com\/ro\/wp-json\/wp\/v2\/product_cat?post=159483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}